Home » Products » Stonewool » Pitched roof

Pitched roof

Any building of new garrets and mansards or any reconstruction of the roof spaces and their conversion to mansard shall require a  perfect project documentation and excellent realisation in consideration of physical characteristics, constructional requirements and standards for energy efficiency. Basic design concept consists of optimal designed and right inbuilt thermal insulation and its protection. Thickness and methods for application of thermal insulation would have resulted from the heat loss calculation. By using the heat loss calculation we can also specify water vapour condensation and consequently to project an sufficient vapour barrier and diffusion foil or extremely diffusion foil as a safety waterproof layer and necessary design element of the sloping roof. In this way we can act to maximize optimal thermal comfort in the living zone with the noise elimination and significant  saving on energy costs as well.

The main principles of heat cladding for sloping roofs (garrets, attics, mansards):

  • to choose - to design a right type and adequate thickness of thermal insulation
  • to provide a secure air circulation through the air gap 
  • to lay thermal insulation continuous without thermal bridges -  the best solution is  thermal insulation applied as a complete layer over the rafters
  • to apply a necessary protective foils - sufficient vapour barrier on the interior side and diffusion foil or extremely diffusion foil on the exterior side
ProductDescriptionApplicationCertification
 
FKD

NOBASIL FKD

MW-EN 13162-T5-DS(TH)-WS-WL(P)
MW-EN 13162-T5-DS(TH)-CS(10)40-TR15-WS-WL(P)-MU1,4
EC certificate of compliance Reg.-Nr.: K1-0751-CPD-146.0-01-01/07

insulation of exterior walls from the outside

more info

Walls
 
PTN

NOBASIL PTN

MW-EN 13162-T6-DS(TH)-CP5-SD20-WS-WL(P)
MW-EN 13162-T6-DS(TH)-CP5-SD15-WS-WL(P)
MW-EN 13162-T6-DS(TH)-CP5-SD10-WS-WL(P)
EC certificate of compliance Reg. No.: K1-0751-CPD-146.0-01-01/07

insulation for floors

more info

Floating floors-hard
Floors
 
MPN

NOBASIL MPN

Technical certificate: MW-EN 13162-T5-DS(TH)-WS-WL(P)-AF5
EC certificate of compliance Reg. No.: K1-0751-CPD-146.0-01-01/07

insulation of pitched roofs and internal structures

more info

Floors
Grilage floor systems
Rafter Level
Suspended Ceiling
 
HTB

NOBASIL HTB (TDN)

Technical certificate: TO 06/0020
Certificate: SK04 - ZSV - 0441

technical insulation - for insulation of flat and gently curved industrial (technical) and energetical equipment

more info

Air Conditioning - even surface
Technical insulations
Technological Equipment
 
FKL

NOBASIL FKL

MW-EN 13162-T5-DS(TH)-TR100-WS-WL(P)-MU1
EC certificate of compliance Reg.-Nr.: K1-0751-CPD-146.0-01-01/07

insulation of exterior walls from the outside

more info

Walls
 
PTE

NOBASIL PTE

MW-EN 13162-T6-DS(TH)-CP3-SD30-WS-WL(P)
MW-EN 13162-T6-DS(TH)-CP3-SD25-WS-WL(P)
MW-EN 13162-T6-DS(TH)-CP3-SD20-WS-WL(P)
MW-EN 13162-T6-DS(TH)-CP3-SD15-WS-WL(P)
EC certificate of compliance Reg.-Nr.: K1-0751-CPD-146.0-01-01/07 

insulation of floors

more info

Floating floors-hard
Floors
 
MPE

NOBASIL MPE

MW-EN 13162-T5-DS(TH)-WS-WL(P)-AF5
EC certificate of compliance Reg.-Nr.: K1-0751-CPD-146.0-01-01/07  

insulation of pitched roofs and internal structures

more info

 
NOBASIL TDN 50

NOBASIL TDN 50

Technical certificate: TO 06/0020
Certificate: SK04 - ZSV - 0441

technical insulation - for insulation of flat and gently curved industrial (technical) and energetical equipment

more info

Air Conditioning - even surface
Technical insulations
Technological Equipment
 
FRN

NOBASIL FRN

MW-EN 13162-T5-DS(TH)-TR1-WS-WL(P)-MU1,4-AF5
EC certificate of compliance Reg.-Nr.: K1-0751-CPD-146.0-01-01/07

insulation of exterior walls from the outside

more info

Walls
 
PTS

NOBASIL PTS

MW-EN 13162-T7-DS(TH)-CP2-SD40-WS-WL(P)
MW-EN 13162-T7-DS(TH)-CP2-SD35-WS-WL(P)
MW-EN 13162-T7-DS(TH)-CP2-SD30-WS-WL(P)
MW-EN 13162-T7-DS(TH)-CP2-SD25-WS-WL(P)
MW-EN 13162-T7-DS(TH)-CP2-SD20-WS-WL(P)
MW-EN 13162-T7-DS(TH)-CP2-SD15-WS-WL(P)
EC certificate of compliance Reg.-Nr.: K1-0751-CPD-146.0-01-01/07 

insulation of floors

more info

Floating floors-light
Floors

Website Options